What size furnace does a 2000 sq ft house in Tacoma, WA need?
| Furnace input rating to buy | 100,000BTU/hr |
|---|---|
| Heat actually delivered100,000 × 96% AFUE — the number that heats the house | 96,000BTU/hr |
| Calculated heat loss2,000 ft² × 40 BTU/ft² | 80,000BTU/hr |
| Winter design temperature99% design dry bulb, 2015–2024 — colder on about 4 days a year | 19°F |
| Design temperature difference70°F indoors against 19°F outdoors — this sets the whole calculation | 51°F |
| Heat loss per square foot9.4 + 0.60 × 51°F | 40BTU/ft² |
| Heating degree daysbase 65°F, annual average | 4,974°F-days |
| Nights at or below freezing | 60nights/yr |
| Gas used per heating seasonfrom measured household consumption, not from the sizing figure above | 708therms |
| Heating cost per yearat $1.42/therm, the national residential average | $1,005 |
| Oversize after rounding upwithin the normal step | 20% |
| Same house at a 35°F design day | 60,800BTU/hr |
| Same house at a −20°F design day2.09× spread for the identical building | 126,800BTU/hr |
Notes
- Tacoma designs to 19°F, and that single number drives everything above. Heat loss is very close to a straight line in the indoor–outdoor difference, so a 51°F design difference gives 40 BTU per square foot per hour. The same house needs 61 MBH on a 35°F design day and 127 MBH at −20°F — a factor of 2.09, which is why a national "40 BTU per square foot" figure is useless in both directions.
- Two BTU numbers, and the box shows the bigger one. A 100,000 BTU/hr furnace at 96% AFUE puts 96,000 BTU/hr into the house; the rest goes up the flue. condensing, the common high-efficiency tier. The mistake to avoid is keeping the old input rating when moving to a higher efficiency — swapping an 80% unit for a 96% unit at the same input adds 16,000 BTU/hr of delivered heat the house never asked for.
- Oversizing is the expensive mistake, not undersizing. An oversized furnace satisfies the thermostat in a few minutes, shuts off, and repeats — hard on the heat exchanger and the igniter, and it leaves the house with hot-then-cold swings and cold rooms at the ends of the duct runs. Undersizing costs comfort on the four coldest nights of the year; oversizing costs comfort on all of them.
- Fuel, roughly — and it does not come from the number above. 4,974 heating degree days on a 2,000 ft² house works out to about 708 therms a season, 1,005 dollars at the national average gas price. That figure is calibrated against what households actually burn, not scaled from the sizing rule of thumb — and the two disagree by a factor of about 2.8, because the sizing table is deliberately conservative. Going from 80% to 96% AFUE here saves roughly $201 a year against an installed price difference usually in the $1,000–2,000 range, so the payback is a real calculation and not an obvious yes.
- This is a heat loss estimate, not a Manual J. The real one counts window area and orientation, insulation R-values, measured air leakage, ceiling height, duct location and how many people live in the house. A tight new build in Tacoma can come in a third below this figure; a 1950s house with original windows and no wall insulation can come in a third above. Ask for the Manual J before signing — it costs a few hundred dollars on a $5,000–10,000 installation, and it is the only thing that turns the number above into a specification.
- Where the design temperature comes from. It is the 1st percentile of daily low temperatures at Tacoma / McChord Air Force Base, 12 km from downtown Tacoma, over 2015–2024 — the same kind of airport station ASHRAE measures at. The percentile was calibrated against eight airports with published ASHRAE values and reproduces them to within 2.2°F on average. Expect a degree or two of difference from a printed table; that is far smaller than the uncertainty in the house itself.
The short answer
A 2000 square foot house in Tacoma, WA needs a furnace rated about 100,000 BTU per hour of input at 96% AFUE, which delivers 96,000 BTU/hr into the house.
Where that number comes from
Tacoma, WA designs to 19°F — the temperature it drops below on roughly four nights a year. Against 70°F indoors that is a 51°F difference, and heat loss is very nearly a straight line in that difference: 40 BTU per square foot per hour here.
This is the reason a single national "40 BTU per square foot" figure is wrong in both directions. The same house wants 60,800 BTU/hr where the design night is 35°F and 126,800 BTU/hr where it is −20°F.
Input is not output
The rating on the box is fuel burned, not heat delivered. At 96% AFUE a 100,000 BTU/hr furnace puts 96,000 BTU/hr into the rooms. Keeping the old input rating when moving to a higher efficiency is the most common way a replacement ends up oversized.
What it costs to run
Tacoma, WA runs 4,974 heating degree days a year. This house at 96% AFUE burns roughly 708 therms a season — about $1,005 at the national average gas price.
Before you buy
Ask for the Manual J. A few hundred dollars on a five-figure installation, and it is the only thing that turns the estimate above into a specification.
Nearby sizes
- What size furnace does a 2000 sq ft house in Paradise, NV need?
- What size furnace does a 2000 sq ft house in Jamaica, NY need?
- What size furnace does a 2000 sq ft house in Richmond, VA need?
- What size furnace does a 2000 sq ft house in Salt Lake City, UT need?
- What size furnace does a 1800 sq ft house in Tacoma, WA need?
- What size furnace does a 2200 sq ft house in Tacoma, WA need?
- What size furnace does a 1600 sq ft house in Tacoma, WA need?
- What size furnace does a 2400 sq ft house in Tacoma, WA need?
Read more
- Five Signs the Furnace Is Too Big for the HouseThe furnace heats the house quickly and then stops. That is the complaint, even though it sounds like a compliment.
- What Size Furnace — BTU Per Square Foot, and Why Input Is Not OutputA 100,000 BTU furnace at 80% AFUE delivers 80,000. Sizing against the wrong one of those two numbers is a 25% error before anything else goes wrong.
- The New Furnace Has to Live in the Old DuctworkThe equipment is chosen from a catalogue. The ducts are whatever the house already has, and they decide what the equipment can deliver.
- Insulating the House Changes the Furnace It NeedsEvery improvement to the envelope is a reduction in required BTU, and it only counts if the sizing happens afterwards.